Certification Body Name:
SEP - BBJ - Stowarzyszenie Elektrykow Polskich - Biuro Badawcze ds. Jakosci

Back to members

 

CB Acronym: SEP - BBJ ID #: 28
Url: http://www.bbj.pl Email:
Phone: Fax: +48 22 812 69 56
Address 1: ul. M. Pozaryskiego 28
Address 2:
City: Warsaw Postal code: 04703
State / Province: PL Country: Poland
Deadline for the next Re-assessment: 2027-11-14
Comments:

Please contact Mr Marcin Ocioszyński for the ENEC, ENEC+ and CCA Schemes requests. Please contact Ms Anna Wronska for HAR Scheme requests

Contact person: Marcin Ocioszynski Email address: M.Ocioszynski@bbj.pl
Business phone: +48 22 812 69 38 Fax: +48 22 812 69 56
Mobile phone:

Aditionnal contacts informations

Anna Wronska

Email address: a.wronska@bbj.pl Fax:
Business phone: Mobile phone:

 

ENEC ENEC Plus CCA
HAR CIG
CB SEP - BBJ - Product Category
CABL
CONT
INST
LITE
MISC
PROT
SAFE
Laboratory Name Acronyme Country City
Stowarzyszenie Elektrykow Polskich - Biuro Badawcze ds. Jakosci SEP - BBJ Lublin Poland Lublin
Stowarzyszenie Elektryków Polskich -Biuro Badawcze ds. Jakosci SEP - BBJ Warsaw Poland Warsaw
E-CTF type E-CTF Laboratory Name E-CTF Address E-CTF Country Standards Covered Registration date Latest Revision date Report Ref.
E-CTF-3 Glamox Testing Laboratory ul. Przemyslowa 2, 30-701 Krakow Poland EN IEC 60598-1:2020 All clauses except 4.4.4; 4.13.1; 4.13.4; 4.13.6; 4.14.1 e); 4.18; 4.20; 4.21.4; 4.26; 4.34, 4.35, 9.2.3; 9.2.10; 9.2.11; 12.3 and 12.4 (accepted to 35°C); 12.5.1 (accepted for LED light sources); 13.3.1; 13.4; EN IEC 60598-1:2021/A11:2022 All clauses except 4.4.4; 4.13.1; 4.13.4; 4.13.6; 4.14.1 e); 4.18; 4.20; 4.21.4; 4.26; 4.34, 4.35, 9.2.3; 9.2.10; 9.2.11; 12.3 and 12.4 (accepted to 35°C); 12.5.1 (accepted for LED light sources); 13.3.1; 13.4; EN IEC 60598-2-1:2021; EN IEC 60598-2-2:2024; EN 60598-2-3:2003; EN 60598-2-3:2003/A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-8:2013; EN IEC 60598-2-22:2022; EN 60598-2-25:1994; EN 60598-2-25:1994/A1:2004; EN IEC 62031:2020; EN IEC 62031:2020/A11:2021; EN 62471:2008; EN 62262:2002 Accepted to IK10 (without IK11); EN 62262:2002/A1:2021 Accepted to IK10 (without IK11) 2014-07-07 2025-10-28 ETICS-BBJ-012-GXk-2025
E-CTF-3 MST Sp. z o.o. Sp. k. ul. Chrobrego 8, 11-400 Ketrzyn, POLAND Poland EN IEC 62031:2020 All causes except: 7, 16, 17 (18.2 PCB, 18.5), 21 EN IEC 62031:2020/A11:2021 All causes except: 7, 16, 17 (18.2 PCB, 18.5), 21 EN 61347-1:2015 All causes except: 8, 17, 18.2 EN 61347-1:2015/A1:2021 All causes except: 8, 17, 18.2 EN 61347-2-13:2014 All causes except: 9 (8), 18 (17), 19 (18.2 PCB) EN 61347-2-13:2014/A1:2017 All causes except: 9 (8), 18 (17), 19 (18.2 PCB) EN IEC 62384:2020 EN 62717:2017 EN 62717:2017/A2:2019 PD EPRS 001 - May 2018 PD EPRS 001 - April 2025 2025-06-04 2026-01-08 ETICS-BBJ-002-MS-2025
E-CTF-3 Glamox Testing Laboratory ul. Olsztynska 2, 11-500 Wilkasy Poland EN IEC 60598-1:2020 All clauses except 4.4.4; 4.13.1; 4.13.4; 4.13.6; 4.14.1 e); 4.18; 4.20; 4.21.4; 4.24; 4.26; 4.28; 4.34, 4.35,5.2.10.3&4; 5.2.14;5.3; 8.2.7; 9.2.3; 9.2.10; 9.2.11; 10.3; 12.3 and 12.4 (accepted to 55°C); 12.5.1 (accepted for LED light sources); 13.2.1; 13.3.1;13.3.2 13.4; 14; 15; EN IEC 60598-1:2021/A11:2022 All clauses except 4.4.4; 4.13.1; 4.13.4; 4.13.6; 4.14.1 e); 4.18; 4.20; 4.21.4; 4.24; 4.26; 4.28; 4.34, 4.35,5.2.10.3&4; 5.2.14;5.3; 8.2.7; 9.2.3; 9.2.10; 9.2.11; 10.3; 12.3 and 12.4 (accepted to 55°C); 12.5.1 (accepted for LED light sources); 13.2.1; 13.3.1;13.3.2 13.4; 14; 15; EN IEC 60598-2-1:2021; EN IEC 60598-2-2:2024; EN 60598-2-3:2003 All clauses except 3.6.5.2.1; 3.6.5.2.2; EN 60598-2-3:2003/A1:2011 All clauses except 3.6.5.2.1; 3.6.5.2.2; EN 60598-2-4:2018 All clauses except 4.7.3/4.13; EN 60598-2-5:2015 All clauses except 5.6.8.2.1; EN 60598-2-8:2013 All clauses except 8.6.6.2; 8.7.6.1; 8.7.6.2; 8.10.4.1; 8.11.4.1; 8.13.1; 8.15.1; 8.16.1; EN IEC 60598-2-22:2022 All clauses except 22.19; EN 60598-2-25:1994 All clauses except 25.6.2.2; 25.6.2.3; 25.10.3.1; 25.12. 3, 25.15.1; EN 60598-2-25:1994/A1:2004; EN IEC 62031:2020 All clauses except 9; 12; 17 ;18; 20; 21 ; Annex A; Annex D; EN IEC 62031:2020/A11:2021 All clauses except 9; 12; 17 ;18; 20; 21 ; Annex A; Annex D 2025-11-05 2025-11-05 ETICS-BBJ-001-GXw-2025
E-CTF-3 Glamox Testing Laboratory Birger Hatlebakksveg 15, 6415 Molde NORWAY EN IEC 60598-1:2021 All clauses except 4.4.4; 4.13.4; 4.13.6; 4.14.1 e); 4.18.2; 4.21.4; 4.24; 4.26; 4.28; 4.34, 4.35, 9.2.3; 9.2.10; 9.2.11; 12.3 and 12.4 (accepted to 60°C); 12.5.1 (accepted for LED light sources); 13.3.2; 13.4; EN IEC 60598-1:2021/A11:2022 All clauses except 4.4.4; 4.13.4; 4.13.6; 4.14.1 e); 4.18.2; 4.21.4; 4.24; 4.26; 4.28; 4.34, 4.35, 9.2.3; 9.2.10; 9.2.11; 12.3 and 12.4 (accepted to 60°C); 12.5.1 (accepted for LED light sources); 13.3.2; 13.4; EN IEC 60598-2-1:2021; EN IEC 60598-2-2:2024; EN 60598-2-3:2003; EN 60598-2-3:2003/A1:2011; EN 60598-2-4:2018; All clauses except 4.7.3/4.13; EN 60598-2-5:2015; EN 60598-2-8:2013 All clauses except 8.6.6.2; 8.10.4.1; 8.15.1; EN 62262:2002; EN 62262:2002/A1:2021; 2025-11-04 2025-11-04 ETICS-BBJ-002-GXm-2025
Scheme Given name Family name Location Certification decision Signatory Scope limitation Terminated
CCA, ENEC, ENEC+, HAR Marcin Ocioszynski Warsaw 2024-06-01 2022-01-01
CCA, ENEC, ENEC+, HAR Andrzej Rybski Warsaw 2018-01-01 2018-01-01 2024-06-30
CCA, ENEC, ENEC+, HAR Zbigniew Brzozowski Warsaw 2009-01-01 2009-01-01 2022-09-06
CCA, ENEC, ENEC+, HAR Kamil Misztal Warsaw 2022-01-01 2022-01-01
CCA, ENEC, ENEC+, HAR Kamil Dobrowolski Warsaw 2022-01-01 2026-01-31
CCA, ENEC, ENEC+, HAR Kamil Wojcicki Poland 2026-05-22
Given name Family name Location Registered date Terminated date
Andrzej Rybski Poland 2021-06-11 2024-06-30
Kamil Dobrowolski Poland 2021-06-11 2026-01-31
Weronika Sadlowska Poland 2021-06-11 2024-03-31
Anna Wronska Poland 2021-06-11
Dariusz Szczepanowski Poland 2021-06-11 2024-12-31
Kamil Misztal Poland 2021-06-11
Jaroslaw Jesien Poland 2021-06-11
Marek Kozlowski Poland 2021-06-11 2024-05-31
Robert Junak Poland 2021-06-11
Marek Krzyszton Poland 2021-06-11
Wojciech Czerwonka Poland 2024-01-01 2024-08-31
Pawel Sadowski Poland 2024-05-01 2024-12-31
Kamil Wojcicki Poland 2025-03-01
Jozef Stanczuk Poland 2025-07-21
Mateusz Przewozny Poland 2025-09-05