Certification Body Name:
OVE - Austrian Electrotechnical Association Testing & Certification

Back to members

 

CB Acronym: OVE ID #: 11
Url: http://www.ove.at Email:
Phone: Fax: + 43 1370 58 06
Address 1: Eschenbachgasse 9
Address 2:
City: Vienna Postal code: 1010
State / Province: AT Country: Austria
Deadline for the next Re-assessment: 2028-10-16
Comments:

Contact person: Thomas Neumayer Email address: T.Neumayer@ove.at
Business phone: + 43 1 370 58 06 Fax: + 43 1370 58 06
Mobile phone:

 

ENEC ENEC Plus CCA
CCA-EMC HAR CIG
CB OVE - Product Category
CABL
CONT
HOR
HOUS
INST
ITAV
LITE
SAFE
Laboratory Name Acronyme Country City
AIT Austrian Institute of Technology GmbH AIT Austrian Institute of Technology GmbH Austria VIENNA
Cooperative Testing Institute Vienna CTI-Vienna Austria VIENNA
Municipal Department 39 - Research center MA 39-VFA Austria Vienna
Technologisches Gewerbemuseum – Höhere Technische Bundes-Lehr- und Versuchs TGM-VAEE Austria Vienna
TÜV Austria Services GmbH TuV (Austria) Austria Wien
E-CTF type E-CTF Laboratory Name E-CTF Address E-CTF Country Standards Covered Registration date Latest Revision date Report Ref.
E-CTF 2 K & N Schalterentwicklungs Ges.m.b.H 1181 Vienna, Schumanngasse 39 Austria EN 60947-1: Annex Q: Categories A and B only. EN 60947-3: All clauses except test sequence IV, Test sequences I, II and III limited to 200A max. EN 60947-4-1: All clauses except test sequence 3, Test sequences 2 and 4 limited to 200A max. EN 60947-5-1: All clauses except test sequence IV. 2008-06-19 2020-12-09 OVE 2022-05
E-CTF-3 ZG Lighting France 27705 Les Andelys, Route de Paix France EN 60598-1: limited to IP-Codes 1st No. 1 to 4, 2nd No. 5 to 7, excl. rough service luminaires and PTI test; EN 60598-2-3: All clauses; EN 60598-2-5: All clauses. 2015-10-01 2021-12-07 OVE_2022-03
E-CTF-3 Thorn Lighting Limited DL16 6HL, Butchers Race Spennymoor, County Durham United Kingdom EN 60598-1: excluded tests for rough service luminaires and PTI test; EN 60598-2-1: All clauses; EN 60598-2-2: All clsuses; EN 60598-2-3: All clsuses; EN 60598-2-5: All clauses; EN 60598-2-22: All clauses; EN 60598-2-24: All clsuses. 2015-10-01 2017-11-03 RAR 85175-0005
MPL ZG Lighting France 27705 Les Andelys, Route de Paix France PD EPRS 002; PD EPRS 003: Restricted to type A luminaires. 2015-10-01 2021-12-07 OVE 2022-03
ENEC+ MPL Zumtobel Lighting GmbH Schweizer Str. 30, 6851 Dornbirn Austria PD EPRS 001; PD EPRS 002; PD EPRS 003 2015-10-01 0000-00-00 OVE 2015/01_MPL
ENEC+ MPL Thorn Lighting Limited DL16 6HL, Butchers Race Spennymoor, County Durham United Kingdom PD EPRS 002; PD EPRS 003: restricted to type A luminaires. 2015-10-01 0000-00-00 OVE 2015/03_MPL
E-CTF-3 Zumtobel Lighting GmbH 6851 Dornbirn, Schweizer Str. 30 Austria EN 60570: All clauses; EN 60598-1 excluded test for rough service luminaires and PTI test, tests for screwless terminals acc. to Clause 15; EN 60598-2-1: All clauses; EN 60598-2-2: All clauses; EN 60598-2-3; All clauses; EN 60598-2-4: All clauses; EN 60598-2-5: All clauses; EN 60598-2-22: All clsuses; EN 60598-2-24: All clauses; EN 62031: All clauses. 2015-10-01 2024-12-16 RAR 251-0006-1
E-CTF-3 Zumtobel Lighting GmbH 32657 Lemgo, Grevenmarschstraße 74-78 Germany EN 60570: All clauses; EN 60598-1: excluded tests for rough service luminaires and PTI test; EN 60598-2-1: All clsuses; EN 60598-2-2: All clauses; EN 60598-2-4: All clauses. 2015-10-01 2018-01-15 RAR 22159-0005
E-CTF-2 PC Electric Ges.m.b.H. 4973 St. Martin im Innkreis, Diesseits 145 Austria EN 60309-1: except Cl. 20, 21; EN 60309-2: except Cl. 20, 21; EN 60309-4: except Cl. 20, 21. 2014-10-17 2022-06-03 CTI - Proj. 758-1
E-CTF-2 Benedict GmbH 1220 Vienna, Lieblgasse 7 Austria EN 60947-1; EN 60947-3: Test sequencies I to V except clauses 9.3.4.3, 9.3.6.2, 9.3.6.3, 9.3.7.2, 9.3.7.3 and decree of protection, EN 60947-4-1: except test sequence 3, as well as Impulse withstand voltage tests and verification of degree of protection; EN 60947-5-1; except test sequence IV, Impulse withstand voltage tests and degree of protection. 2005-02-12 2018-08-06 CTI-Proj. 755-1
E-CTF-3 Tridonic GmbH & Co KG 6851 Dornbirn, Färbergasse 15 Austria EN 60598-1: Accepted clauses: Only tests as required by IEC 61347-1 for independent controlgears: Cl. 0, 2, 3, 4, 5, 7, 8, 9, 10, 11, 12, 13; EN 61347-1: All clauses exexpt resistance to corrosion; EN 61347-2-7: All clauses; EN 61347-2-11: All clauses; EN 61347-2-13: All clauses; EN 61547: Only for testing electronic controlgears as required by EN 61347-2-13 Annex J. EN 62031: All clauses except PTI test; EN 62471, resistance to corrosion; EN 62384: All clauses. 2004-09-01 2020-11-28 RAR 7590-0004
E-CTF-3 Tridonic GmbH & Co KG Technologiepark 10, 8380 Jennersdorf Austria EN 61347-1: All clauses, except Cl. 10.1, 18, 19, Annex N; EN 61347-2-13: All clauses except Cl. 8, 19, 20, Annex J; EN 62031: All clauses except Cl. 18, 19 and blue light hazard; EN IEC 62031: All clauses except Cl. 17, 18, 21; EN 62384: All clauses except Cl. 11; EN IEC 62384: All clauses. 2014-05-27 2021-12-21 RAR 66301-0005
E-CTF-2 SCHNEIDER-ELECTRIC F-Lab 38050 Grenoble, 28, Rue Henri Tarze France EN 60898-1: All clauses; EN 60947-1: only in conjunction with EN 60947-2; EN 60947-2 (F-Lab Amplitude max. 35kA); EN 61008-1: EMC-requirements excluded; EN 61008-2-1: All clauses; EN 61009-1: EMC-requirements excluded; EN 61009-2-1: All clauses; EN 62606: EMC-requirements excluded 2018-12-06 2022-01-04 OVE_2022-04
E-CTF-3 TridonicAtco (Shenzhen) Co., Ltd. 3F, Block 6, Building A3, No.130, Park 3 Silicon Valley Power Ind., Si Li Road, Ku Keng Community, Guanlan Street, Long Hua District, Shenzhen China EN 60598-1:Accepted clauses: Only tests as required by IEC 61347-1 for independent controlgears: Cl. 0, 2, 3, 4, 5, 7, 8, 9, 10, 11, 12, 13; EN 61347-1: except resistance to corrosion; EN 61347-2-11: All clauses; EN 61347-2-13: All clauses; EN 61547: Only for testing electronic controlgears as required by EN 61347-2-13 Annex J; EN 62384: except Cl. 11. EN IEC 62384: All clauses. 2018-11-30 2022-02-23 RAR 87837-0007
E-CTF 2 Eaton Industries (Austria) Performance Verification Lab (PVL) Scheydgasse 42 1210 Wien Austria EN 60947-1: Only in conjunction with EN 60947-2. EN 60947-2: Accepted clauses 8.3.4 and 8.3.5. EN 60898-1: Accepted clause 9.12 EN 61008-1: Accepted clause 9.11 EN 61008-2-1: Accepted clause 9.11 EN 61009-1: Accepted clause 9.12 EN 61009-2-1: Accepted clause 9.12 2019-09-19 0000-00-00 OVE_2019-04
E-CTF-2 ETI Elektroelement d.o.o. Obrezija 5 1411 Izlake Slovenia EN 60947-1: Only Clauses 9.2.2.1, 9.2.5.2, 9.2.5.3, 9.2.5.4, 9.3.3.3, 9.3.3.4.; EN 60947-3: Only Clauses 9.2.5, as well as: TSQ I (9.3.4): 9.3.4.2, 9.3.4.3, 9.3.4.5, 9.3.4.6, 9.3.4.7, 9.3.4.8. TSQ II (9.3.5): 9.3.5.3, 9.3.5.4, 9.3.5.5. TSQ III (9.3.6): 9.3.6.4, 9.3.6.5, 9.3.6.6. TSQ IV (9.3.7): 9.3.7.4, 9.3.7.5, 9.3.7.6. TSQ V (9.3.8): 9.3.8.2, 9.3.8.3, 9.3.8.4, 9.3.8.5.; EN 60269-1: Only Clauses 8.1.4, 8.1.5.1, 8.2, 8.3, 8.4.3.1 a), 8.4.3.1 b), 8.4.3.2, 8.4.3.3 (up to 125A), 8.4.3.4, 8.4.3.5, 8.4.3.6, 8.6, 8.7, 8.9, 8.10, 8.11.1, 8.11.2.2, 8.11.2.3.; EN 60269-2: Only Clauses 8.1.4, 8.1.5.1, 8.2, 8.3.4.1, 8.3.4.2, 8.4.3.1 a), 8.4.3.1 b), 8.4.3.2, 8.4.3.5, 8.7.4, 8.9, 8.10, 8.11.1.1, 8.11.1.2, 8.11.2.3, 8.11.2.4, Annex AA.; EN 60269-3: Only Clauses 8.1.4, 8.1.5.1, 8.2, 8.3.4.1, 8.3.4.2, 8.4.3.1 a), 8.4.3.1 b), 8.4.3.2, 8.4.3.5, 8.7.4, 8.9, 8.10, 8.11.1.1, 8.11.1.2, 8.11.1.3, 8.11.1.4, 8.11.2.3, 8.11.2.4, 8.11.2.6, Annex AA.; EN 60269-4: Only Clauses 8.3, 8.3.4.1, 8.3.4.2, 8.4.3.3.1, 8.4.3.4, 8.4.3.5, 8.4.3.6, 8.6, 8.7.; EN 60898-1: Only Clauses 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.9, 9.10, 9.11, 9.13, 9.12.12.; IEC 61008-1; ; EN 61008-2-1: Only Clauses 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.9 (50Hz, 60Hz up to 5A), 9.10, 9.12, 9.13, 9.14, 9.15, 9.16, 9.18, 9.19, 9.22, 9.23; EN 61009-1: Only Clauses 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.9.1 (50Hz, 60Hz up to 5A), 9.9.2, 9.10, 9.11, 9.12.12, 9.13, 9.14, 9.15, 9.16, 9.19, 9.22, 9.23.; EN 61009-2-1: All Clauses as for IEC/EN 61009-1. 2021-05-10 2022-11-09 ETI/RA/2024-11
E-CTF-2 Tridonic UK Limited House of Light, Butchers Race, Green Lane Industrial Estate Spennymoor, Co Durham DL16 6JE United Kingdom EN 61347-1: All clauses, excluding PTI test, and resistance to corrosion; EN 61347-2-7: All clauses; EN 61347-2-11: All clauses; EN 61347-2-13: All clauses; EN IEC 62384: All clauses. 2025-03-28 2025-03-28 IAR 22175-0001
Scheme Given name Family name Location Certification decision Signatory Scope limitation Terminated
ENEC, CCA, HAR Wolfgang Martin Vienna 1993-01-01 1993-01-01 none 2021-03-31
ENEC, CCA, HAR Matthias Neugebauer Vienna 2017-02-28 2017-02-28 none
ENEC, CCA, HAR Rudolf Stögmüller Vienna 2016-08-01 2016-08-01 none 2021-09-01
ENEC, CCA, HAR Thomas Neumayer Vienna 2021-04-01 2021-04-01 none
Given name Family name Location Registered date Terminated date
Thomas Neumayer Austria 2021-03-31
Andreas Marek Austria 2021-03-31
Markus Obritzhauser Austria 2021-03-31
Claus Ruprechter Austria 2021-03-31