Certification Body Name:
OVE - Austrian Electrotechnical Association Testing & Certification

Back to members

 

CB Acronym: OVE ID #: 11
Url: http://www.ove.at Email:
Phone: Fax: + 43 1370 58 06
Address 1: Eschenbachgasse 9
Address 2:
City: Vienna Postal code: 1010
State / Province: AT Country: Austria
Deadline for the next Re-assessment: 2025-10-16
Comments:

Contact person: Thomas Neumayer Email address: T.Neumayer@ove.at
Business phone: + 43 1 370 58 06 Fax: + 43 1370 58 06
Mobile phone:

 

CCA-EMC
CB OVE - Product Category
Laboratory Name Acronyme Country City
Cooperative Testing Institute Vienna CTI-Vienna Austria VIENNA
Technologisches Gewerbemuseum – Höhere Technische Bundes-Lehr- und Versuchs TGM-VAEE Austria Vienna
TÜV Austria Services GmbH TuV (Austria) Austria Wien
E-CTF type E-CTF Laboratory Name E-CTF Address E-CTF Country Standards Covered Registration date Latest Revision date Report Ref.
E-CTF 2 K & N Schalterentwicklungs Ges.m.b.H 1181 Vienna, Schumanngasse 39 Austria EN 60947-1: Annex Q: Categories A and B only. EN 60947-3: All clauses except test sequence IV, Test sequences I, II and III limited to 200A max. EN 60947-4-1: All clauses except test sequence 3, Test sequences 2 and 4 limited to 200A max. EN 60947-5-1: All clauses except test sequence IV. 2008-06-19 2020-12-09 OVE 2022-05
E-CTF-3 ZG Lighting France 27705 Les Andelys, Route de Paix France EN 60598-1: limited to IP-Codes 1st No. 1 to 4, 2nd No. 5 to 7, excl. rough service luminaires and PTI test; EN 60598-2-3: All clauses; EN 60598-2-5: All clauses. 2015-10-01 2021-12-07 OVE_2022-03
E-CTF-3 Thorn Lighting Limited DL16 6HL, Butchers Race Spennymoor, County Durham United Kingdom EN 60598-1: excluded tests for rough service luminaires and PTI test; EN 60598-2-1: All clauses; EN 60598-2-2: All clsuses; EN 60598-2-3: All clsuses; EN 60598-2-5: All clauses; EN 60598-2-22: All clauses; EN 60598-2-24: All clsuses. 2015-10-01 2017-11-03 RAR 85175-0005
MPL ZG Lighting France 27705 Les Andelys, Route de Paix France PD EPRS 002; PD EPRS 003: Restricted to type A luminaires. 2015-10-01 2021-12-07 OVE 2022-03
ENEC+ MPL Zumtobel Lighting GmbH Schweizer Str. 30, 6851 Dornbirn Austria PD EPRS 001; PD EPRS 002; PD EPRS 003 2015-10-01 0000-00-00 OVE 2015/01_MPL
ENEC+ MPL Thorn Lighting Limited DL16 6HL, Butchers Race Spennymoor, County Durham United Kingdom PD EPRS 002; PD EPRS 003: restricted to type A luminaires. 2015-10-01 0000-00-00 OVE 2015/03_MPL
E-CTF-3 Zumtobel Lighting GmbH 6851 Dornbirn, Schweizer Str. 30 Austria EN 60570: All clauses; EN 60598-1 excluded test for rough service luminaires and PTI test, tests for screwless terminals acc. to Clause 15; EN 60598-2-1: All clauses; EN 60598-2-2: All clauses; EN 60598-2-3; All clauses; EN 60598-2-4: All clauses; EN 60598-2-5: All clauses; EN 60598-2-22: All clsuses; EN 60598-2-24: All clauses; EN 62031: All clauses. 2015-10-01 2024-12-16 RAR 251-0006-1
E-CTF-3 Zumtobel Lighting GmbH 32657 Lemgo, Grevenmarschstraße 74-78 Germany EN 60570: All clauses; EN 60598-1: excluded tests for rough service luminaires and PTI test; EN 60598-2-1: All clsuses; EN 60598-2-2: All clauses; EN 60598-2-4: All clauses. 2015-10-01 2018-01-15 RAR 22159-0005
E-CTF-2 PC Electric Ges.m.b.H. 4973 St. Martin im Innkreis, Diesseits 145 Austria EN 60309-1: except Cl. 20, 21; EN 60309-2: except Cl. 20, 21; EN 60309-4: except Cl. 20, 21. 2014-10-17 2022-06-03 CTI - Proj. 758-1
E-CTF-2 Benedict GmbH 1220 Vienna, Lieblgasse 7 Austria EN 60947-1; EN 60947-3: Test sequencies I to V except clauses 9.3.4.3, 9.3.6.2, 9.3.6.3, 9.3.7.2, 9.3.7.3 and decree of protection, EN 60947-4-1: except test sequence 3, as well as Impulse withstand voltage tests and verification of degree of protection; EN 60947-5-1; except test sequence IV, Impulse withstand voltage tests and degree of protection. 2005-02-12 2018-08-06 CTI-Proj. 755-1
E-CTF-3 Tridonic GmbH & Co KG 6851 Dornbirn, Färbergasse 15 Austria EN 60598-1: Accepted clauses: Only tests as required by IEC 61347-1 for independent controlgears: Cl. 0, 2, 3, 4, 5, 7, 8, 9, 10, 11, 12, 13; EN 61347-1: All clauses exexpt resistance to corrosion; EN 61347-2-7: All clauses; EN 61347-2-11: All clauses; EN 61347-2-13: All clauses; EN 61547: Only for testing electronic controlgears as required by EN 61347-2-13 Annex J. EN 62031: All clauses except PTI test; EN 62471, resistance to corrosion; EN 62384: All clauses. 2004-09-01 2020-11-28 RAR 7590-0004
E-CTF-3 Tridonic GmbH & Co KG Technologiepark 10, 8380 Jennersdorf Austria EN 61347-1: All clauses, except Cl. 10.1, 18, 19, Annex N; EN 61347-2-13: All clauses except Cl. 8, 19, 20, Annex J; EN 62031: All clauses except Cl. 18, 19 and blue light hazard; EN IEC 62031: All clauses except Cl. 17, 18, 21; EN 62384: All clauses except Cl. 11; EN IEC 62384: All clauses. 2014-05-27 2021-12-21 RAR 66301-0005
E-CTF-2 SCHNEIDER-ELECTRIC F-Lab 38050 Grenoble, 28, Rue Henri Tarze France EN 60898-1: All clauses; EN 60947-1: only in conjunction with EN 60947-2; EN 60947-2 (F-Lab Amplitude max. 35kA); EN 61008-1: EMC-requirements excluded; EN 61008-2-1: All clauses; EN 61009-1: EMC-requirements excluded; EN 61009-2-1: All clauses; EN 62606: EMC-requirements excluded 2018-12-06 2022-01-04 OVE_2022-04
E-CTF-3 TridonicAtco (Shenzhen) Co., Ltd. 3F, Block 6, Building A3, No.130, Park 3 Silicon Valley Power Ind., Si Li Road, Ku Keng Community, Guanlan Street, Long Hua District, Shenzhen China EN 60598-1:Accepted clauses: Only tests as required by IEC 61347-1 for independent controlgears: Cl. 0, 2, 3, 4, 5, 7, 8, 9, 10, 11, 12, 13; EN 61347-1: except resistance to corrosion; EN 61347-2-11: All clauses; EN 61347-2-13: All clauses; EN 61547: Only for testing electronic controlgears as required by EN 61347-2-13 Annex J; EN 62384: except Cl. 11. EN IEC 62384: All clauses. 2018-11-30 2022-02-23 RAR 87837-0007
E-CTF 2 Eaton Industries (Austria) Performance Verification Lab (PVL) Scheydgasse 42 1210 Wien Austria EN 60947-1: Only in conjunction with EN 60947-2. EN 60947-2: Accepted clauses 8.3.4 and 8.3.5. EN 60898-1: Accepted clause 9.12 EN 61008-1: Accepted clause 9.11 EN 61008-2-1: Accepted clause 9.11 EN 61009-1: Accepted clause 9.12 EN 61009-2-1: Accepted clause 9.12 2019-09-19 0000-00-00 OVE_2019-04
E-CTF-2 ETI Elektroelement d.o.o. Obrezija 5 1411 Izlake Slovenia EN 60947-1: Only Clauses 9.2.2.1, 9.2.5.2, 9.2.5.3, 9.2.5.4, 9.3.3.3, 9.3.3.4.; EN 60947-3: Only Clauses 9.2.5, as well as: TSQ I (9.3.4): 9.3.4.2, 9.3.4.3, 9.3.4.5, 9.3.4.6, 9.3.4.7, 9.3.4.8. TSQ II (9.3.5): 9.3.5.3, 9.3.5.4, 9.3.5.5. TSQ III (9.3.6): 9.3.6.4, 9.3.6.5, 9.3.6.6. TSQ IV (9.3.7): 9.3.7.4, 9.3.7.5, 9.3.7.6. TSQ V (9.3.8): 9.3.8.2, 9.3.8.3, 9.3.8.4, 9.3.8.5.; EN 60269-1: Only Clauses 8.1.4, 8.1.5.1, 8.2, 8.3, 8.4.3.1 a), 8.4.3.1 b), 8.4.3.2, 8.4.3.3 (up to 125A), 8.4.3.4, 8.4.3.5, 8.4.3.6, 8.6, 8.7, 8.9, 8.10, 8.11.1, 8.11.2.2, 8.11.2.3.; EN 60269-2: Only Clauses 8.1.4, 8.1.5.1, 8.2, 8.3.4.1, 8.3.4.2, 8.4.3.1 a), 8.4.3.1 b), 8.4.3.2, 8.4.3.5, 8.7.4, 8.9, 8.10, 8.11.1.1, 8.11.1.2, 8.11.2.3, 8.11.2.4, Annex AA.; EN 60269-3: Only Clauses 8.1.4, 8.1.5.1, 8.2, 8.3.4.1, 8.3.4.2, 8.4.3.1 a), 8.4.3.1 b), 8.4.3.2, 8.4.3.5, 8.7.4, 8.9, 8.10, 8.11.1.1, 8.11.1.2, 8.11.1.3, 8.11.1.4, 8.11.2.3, 8.11.2.4, 8.11.2.6, Annex AA.; EN 60269-4: Only Clauses 8.3, 8.3.4.1, 8.3.4.2, 8.4.3.3.1, 8.4.3.4, 8.4.3.5, 8.4.3.6, 8.6, 8.7.; EN 60898-1: Only Clauses 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.9, 9.10, 9.11, 9.13, 9.12.12.; IEC 61008-1; ; EN 61008-2-1: Only Clauses 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.9 (50Hz, 60Hz up to 5A), 9.10, 9.12, 9.13, 9.14, 9.15, 9.16, 9.18, 9.19, 9.22, 9.23; EN 61009-1: Only Clauses 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.9.1 (50Hz, 60Hz up to 5A), 9.9.2, 9.10, 9.11, 9.12.12, 9.13, 9.14, 9.15, 9.16, 9.19, 9.22, 9.23.; EN 61009-2-1: All Clauses as for IEC/EN 61009-1. 2021-05-10 2022-11-09 ETI/RA/2024-11
E-CTF-2 Tridonic UK Limited House of Light, Butchers Race, Green Lane Industrial Estate Spennymoor, Co Durham DL16 6JE United Kingdom EN 61347-1: All clauses, excluding PTI test, and resistance to corrosion; EN 61347-2-7: All clauses; EN 61347-2-11: All clauses; EN 61347-2-13: All clauses; EN IEC 62384: All clauses. 2025-03-28 2025-03-28 IAR 22175-0001
Scheme Given name Family name Location Certification decision Signatory Scope limitation Terminated
ENEC, CCA, HAR Wolfgang Martin Vienna 1993-01-01 1993-01-01 none 2021-03-31
ENEC, CCA, HAR Matthias Neugebauer Vienna 2017-02-28 2017-02-28 none
ENEC, CCA, HAR Rudolf Stögmüller Vienna 2016-08-01 2016-08-01 none 2021-09-01
ENEC, CCA, HAR Thomas Neumayer Vienna 2021-04-01 2021-04-01 none
Given name Family name Location Registered date Terminated date
Thomas Neumayer Austria 2021-03-31
Andreas Marek Austria 2021-03-31
Markus Obritzhauser Austria 2021-03-31
Claus Ruprechter Austria 2021-03-31