MTL type |
MTL Laboratory Name |
MTL Address |
MTL Country |
Standards Covered |
Registration date |
Latest Revision date |
Report Ref. |
E-CTF 3 |
Eaton/Cutler-Hammer, Technology and Quality Center |
170, Industry Drive, RIDC Park West, Pittsburgh |
USA |
EN 60947-1; 60947-2; 60947-3; 60898; 60439-1; 60439-2 |
2003-12-15 |
0000-00-00 |
DEKRA-006 |
E-CTF 1 |
BSH Ev Aletleri Sanayi Ve Ticaret A.S. |
Cerkezkoy 59500, Tekirdag |
Turkey |
EN 60335-1; EN 60335-2-6; EN 60335-2-9; EN 60335-2-14 |
2006-09-25 |
0000-00-00 |
DEKRA-027 |
E-CTF 2 |
Techtronic Industries GmbH |
Max-Eyrth-Strasse 10, 71364 Winnenden |
Germany |
EN 60745-1; EN 60745-2; EN 61029-1; EN 61029-2; EN 60335-1; EN 60335-2-45
|
2006-03-28 |
0000-00-00 |
DEKRA-042/WMT |
E-CTF 3 |
Hager Electro S.A.S. |
132 Boulevard d'Europe, 67215 Obernai Cedex |
France |
EN 60269-1; EN 60269-3; EN 60269-3-1; EN 60669-1; EN 60669-2-2; EN 60898-1; EN 60947-1; EN 60947-2; EN 60947-3; EN 61008-1; EN 61008-2-1; EN 61008-2-2; EN 61009-1; EN 61009-2-1; EN 61009-2-2; EN 61095 ; EN 61558-1; EN 61558-2-6; EN 61558-2-8 |
2007-12-07 |
2009-03-30 |
DEKRA-050 |
E-CTF 2 |
EFORE S.p.A. |
Via Jesina, 56/A - 60022 Castelfidardo (AN) |
Italy |
EN 61347-1; EN 61347-2-7; EN 61347-2-13; EN 62384 |
2006-08-11 |
2009-07-02 |
DEKRA-099 |
E-CTF 2 |
Metabowerke GmbH |
Metabo-Allee 1, 72622 Nürtingen |
Germany |
EN 60745-1; EN 60745-2; EN 61029-1; EN 61029-2; EN 60335-1; EN 60335-2-45
|
2006-12-11 |
0000-00-00 |
DEKRA-107 |
E-CTF 2 |
Robert Bosch Power Tools Ltd. |
Free Industrial Zone 1, 11900 Bayan Lepas, Penang |
Malaysia |
EN 60745-1; EN 60745-2; EN 61029-1; EN 61029-2; EN 60335-1; EN 60335-2-45 |
2007-12-18 |
0000-00-00 |
DEKRA-115 |
E-CTF 1 |
Faeber Lighting System S.p.A. |
Via Aldo Moro, 5/11 - 24050 Orio al Serio (BG) |
Italy |
EN 60598-1; EN 60598-2-1; EN 60598-2-2; EN 60598-2-3; EN 60598-2-5 |
2008-01-28 |
2007-07-19 |
DEKRA-135 |
E-CTF 2 |
Power-One Italy S.p.a |
Via San Giorgio, 642 - 52028 Terranuova B.ni (AR) |
Italy |
EN 60950-1; EN 61347-1; EN 61347-2-11; EN 61347-2-12; EN 61347-2-13; EN 62190-1; EN 62109-2 |
2008-04-07 |
2014-10-02 |
DEKRA-149 |
E-CTF 2 |
ETI Elektroelement d.d., Technical Laboratory |
Obrezija 5, 1411 Izlake |
Slovenia |
EN 60898-1; EN 61008-1; EN 61009-1 |
2008-10-20 |
2008-10-20 |
DEKRA-168 |
E-CTF 1 |
ALVIT S.r.l. |
Via Padania, 6 - 20046 Biassono (MB) |
Italy |
EN 61347-1:2008; EN 61347-2-7:2006; EN 61347-2-13:2006; EN 61032:2008; EN 60925:1991+A1:1996+A2:2001; EN 62834:2006. |
2009-03-11 |
0000-00-00 |
DEKRA-185 |
E-CTF 2 |
Saeco International group S.p.A. |
Via Torretta, 240 - 40041 Gaggio Montano (BO) |
Italy |
EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; EN 55022; EN 50366; EN 62233; EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-11; EN 61000-4-13 |
2010-09-06 |
0000-00-00 |
DEKRA-233 |
E-CTF 1 |
Miele & Cie KG |
Mielestrasse 2, 33611 Bielefeld |
Germany |
EN 60335-1; EN 60335-2-2; EN 60335-2-5 |
2006-08-04 |
2009-11-19 |
DEKRA-015/TMP-A |
E-CTF 1 |
Miele & Cie. KG |
Carl-Mielestrasse 29, 33332 Gütersloh |
Germany |
EN 60335-1; EN 60335-2-4; EN 60335-2-7; EN 60335-2-11 |
2005-05-12 |
2010-05-22 |
DEKRA-022/TMP |
E-CTF 2 |
AIMVALLEY B.V. |
Anton Philipsweg 1, 1223 KZ Hilversum |
The Netherlands |
EN 60950 |
2006-09-14 |
2006-09-14 |
DEKRA-080/WMT |
E-CTF 2 |
ERCO GmbH |
Brockhauser Weg 80-82, 58507 Luedenscheid |
Germany |
EN IEC 60598-1:2021 All clauses except the following ones.
4.4.4 (lampholder pressure test), 4.4.5 (voltage across lampholder), 4.20 (vibration test for rough service luminaires), 9.2.1 (IP5X), 9.2.2 (IP6X),13.3.1 (needle flame test), 13.4.1 (resistance to tracking); EN IEC 60598-2-1:2021 All clauses; EN60598-2-2:2012 All clauses; EN 60598-2-3:2003 + A1:2011 All clauses; EN 60598-2-4:2018 All clauses; EN 60598-2-5:2015 All clauses; EN 60598-2-13:2006 + A1:2012 + A2:2016 All clauses; EN 60598-2-18:1994 + A1:2012 All clauses; EN60598-2-22:2014 + A1:2020 All clauses; EN 60570:2003 + A1:2018 + A2:2020 All clauses; EN IEC 62031:2020 All clauses except a.c. supplied LED modules; EN 60838-1:2017 + A1:2017 + A2:2020 + A11:2021 All clauses except 17.4, 17.5, 18.1, 18.2; EN IEC/TR 62778:2014 All clauses |
2011-04-06 |
2015-10-14 |
DEKRA113 |
E-CTF 2 |
Selux AG |
Motzener Strasse 34, 12277 Berlin |
Germany |
EN 60598-1:2021 All clauses except the following: 9.2.1(IP5X) 9.2.2.(IP6X), 13.3.1(needle flame test), 13.3.2(Glow fire), 13.4.1(resistance to tracking); EN 60598-2-1:2021 All clauses; EN 60598-2-2:2012 All clauses; EN 60598-2-3:2003 All clauses; EN 60598-2-3:2003/A1:2011 All clauses; EN 60598-2-5 2015 All clauses; EN 60598-2-22:2014 and EN 60598-2-22:2014/A1:2020 All clauses; EN 61347-1:2015 and EN 61347-1:2015/A1:2021 All clauses except the following: 18 Resistance to heat, fire and tracking; EN 61347-2-11:2001 and EN 61347-2-11:2001/A1:2019 All clauses; EN 62031:2020 All clauses |
2008-01-08 |
2021-03-08 |
DEKRA-126 |
E-CTF 1 |
WIK Far East Limited |
Huangpu 2nd Industrial Estate, Shajing, Baoan, Shenzhen |
China |
EN 60335-1; EN 60335-2-15; EN 60335-2-23; EN 60335-2-14 |
2008-06-04 |
2008-06-04 |
DEKRA-153/TMP |
E-CTF 2 |
HEP GmbH |
Ramsloh 10, 58579 Schalksmühle |
Germany |
EN 61347-1:2015 All clauses except the following ones: Clauses 18.1, 18.3, 18.4 and 18.5; EN 613147-2-2:2012 All clauses except clause 19; EN 61347-2-3:2012 + A1:2017 All clauses except clause 21; EN 61347-2-7:2012 + A1:2019 All clauses except clause 32; EN 61347-2-11-2001 + A1:2019 All clauses except clause 18; EN 61347-2-12:2005 + A1:2010 All clauses except clause 21; EN 613147-2-13:2014 + A1:2017 All clauses except clause 19; EN 60929:2011 + A1:2016 All clauses; EN 61047:2004 All clauses; EN 62384:2006 + A1:2009 All clauses |
2009-05-28 |
2020-09-28 |
DEKRA-193 |
E-CTF 2 |
Italweber Elettra S.r.l. |
Via per Inveruno, 103 - 20020 Busto Garolfo (MI) |
Italy |
EN 61558-1; EN 61558-2-4; EN 61558-2-6; EN 61558-2-13 |
2009-08-04 |
2013-09-19 |
DEKRA-194/WMT |
E-CTF 2 |
Hadler GmbH |
Fritzlarer Strasse 19, 34587 Felsberg-Neuenbrunslar |
Germany |
EN 61347-1:2015 All clauses except cl.11, cl.12 and cl.18; EN 61347-2-3:2011 +
A1:2017 All clauses except cl.11, cl.12 and cl.21; EN 60929:2011 + A1:2016 All clauses except cl. 15.2; EN 61347-2-13:2014 + A1:2017 All clauses except cl.11, cl.12 and cl.19; EN 62384:2006 + A1:2009 All clauses except cl.13.1a; EN 62031 |
2009-01-07 |
2019-06-27 |
DEKRA-204-RA-2019 |
E-CTF 2 |
Prodrive Technologies B.V. |
Science Park Eindhoven 5501, 5692 EM Son |
The Netherlands |
(continue)
[MEAS]
EN 61010-1 (2nd edition) All relevant clauses, except: 12.2.1 (ionizing radiation), 12.3 (UV radiation), 12.4 (microwave radiation), 12.5.1 (sound pressure), 12.5.2 (ultrasonic pressure); IEC 61010-1 (3rd edition) All relevant clauses, except: 12.2 ionizing radiation and accelerated electrons, 12.3 (UV radiation), 12.4 (microwave radiation), 12.5.1 (sound pressure), 12.5.2 (ultrasonic pressure)
[MED]
IEC 60601-1 (2nd edition) All relevant clauses, except: 17 (defibrillator proof testing), 25.2 (expelled parts; no vacuum tubes are used), 29 (radiation meter), 37-41 (tests and requirements for category AP and APG), 44.2-44.4 (overflow, spilage; no liquids), 44.7 (cleaning, sterilization and disinfection; no applied parts), 45 (pressure; no pressure vessel), 59.2c (aging of rubber in oxygen rich environment); IEC 60601-1 (3rd edition) All relevant clauses, except:
8.5.5.1, 8.5.5.2 (energy reduction test; no applied parts), 8.8.4.2 (resistance to environmental stress; aging rubber in oxygen), 9.5.2 (cathode ray tube), 9.6.2.1 (audible acoustic energy), 9.6.3 (hand-transmitted vibrations), 9.7.5 (pressure vessels), 9.8 (hazards associated with support systems), 10.1 (X-ray), 11.2 (ME in conjunction with oxygen rich environment), 11.6.2 (overflow), 11.6.3 (spillage), 11.6.7 (sterilization), G (flammable anaesthetic) |
2010-04-30 |
0000-00-00 |
DEKRA-207 |
E-CTF 2 |
Imperial Werke oHG |
Miele-strasse 1, 59759 Arnsberg |
Germany |
EN 60335-1; EN 60335-2-31 |
2006-08-04 |
2009-11-19 |
DEKRA-210/TMP |
E-CTF 3 |
TCI TELECOMUNICAZIONI ITALIA S.r.l. |
Via Parma, 14 - 21047 Saronno (VA) |
Italy |
EN 61347-1 All, except for clauses: 7.2, 18.2, 18.3 (glow-wire), 18.4, 18.5, 19; EN 61347-2-2; EN 61347-2-3; EN 61347-2-7; EN 61347-2-11; EN 61347-2-12; EN 61347-2-13; EN 60925; EN 60929 All, except for clause 13; EN 61558-1 All, except for clauses: 8.15, pull test device, 17.1, 19.2, 19.9, 19.10, 19.12.3, 19.15, 22.9.4, 22.9.5, 26.3, 27.1, 27.2, 27.4, 27.5, 28; EN 61558-2-1; EN 61558-2-2; EN 61558-2-4; EN 61558-2-6; EN 61558-2-9; EN 61558-2-12; EN 61558-2-20; EN 60598-1 All, except for clauses: 3.4, 4.4.4, 4.12.5, 4.13.1, 4.13.4, 4.13.6, 4.14.1, 4.14.2, 4.21.4, 4.9.2, 4.1.8.1, 4.18.2, Annex F, 4.20, 4.22, Annex P, 4.26, 5.03, 9.2.1, 9.2.2, 9.2.3, 10.3.1, 12.3.1, 13.3.1, 13.3.2, 13.4.1, 14; EN 60598-2-1; EN 60598-2-2 All, except for clause 2.5.1; EN 61558-2-22 All, except for integrator and goniometric; EN 60598-2-23; EN 62384; EN 62031 All, except for clause: 19. |
2010-07-01 |
2015-11-27 |
DEKRA-228 |
E-CTF 2 |
Datalogic Scanning Group S.r.l. |
Via San Vitalino, 13 - 40012 Calderara di Reno (BO) |
Italy |
EN 60950-1 |
2011-06-14 |
0000-00-00 |
DEKRA-249/WMT |
E-CTF 2 |
Datalogic Scanning Group S.r.l./Datalogic Mobile S.r.l. |
Via San Vitalino, 13 - 40012 Calderara di Reno (BO) |
Italy |
EN 60950-1 |
2011-06-28 |
0000-00-00 |
DEKRA-250/WMT |
E-CTF 2 |
Datalogic Automation |
Via Lavino, 265 - 40050 Monte San Pietro (BO) |
Italy |
EN 60950-1 |
2011-06-20 |
0000-00-00 |
DEKRA-253/WMT |
E-CTF 3 |
Magnetic Systems Technology Sp.zo.o.Sp.k. |
ul. B. Chrobrego 8, 11 400 Ketrzyn |
Poland |
EN 61347-2-1; EN 61347-2-8; EN 61347-2-9; EN 60921; EN 60923; EN 60925 |
2011-07-07 |
0000-00-00 |
DEKRA-254/SMT |
E-CTF 2 |
Esaote S.p.A. |
Via di Caciolle, 15 - 50127 Firenze |
Italy |
EN 60601-1; EN 60601-2-37 |
2011-08-02 |
0000-00-00 |
DEKRA-256/WMT |
E-CTF 1 |
Faro S.p.A. |
Via Faro, 15 - 20876 Ornago (MB) |
Italy |
EN 60601 |
2011-08-01 |
0000-00-00 |
DEKRA-257/TMP |
E-CTF 3 |
Philips (China) Investment Co., Ltd. |
Lighting Test Centre - LTC No. 9, Lane 888, Tian Lin Road, 200233 Shanghai |
China |
IEC/EN 60968; IEC/EN 60432-1; IEC/EN 60432-2 except cl 2.11-UV radiation; IEC/EN 60432-3 except cl 2.4-UV radiation; IEC/EN 62560; IEC-EN 61199; IEC/EN 61195; IEC/EN 62031; IEC/EN 60682; IEC/EN 61341; IEC/EN 62776; EC 244 UV radiation; EC 859; EC 1194; ZHAGA-book7 cl 4.5-luminance uniformity; IEC/EN 60969; IEC/EN 60901; IEC/EN 60081; IEC/EN 60064; IEC/EN 60357; IEC/EN 62612; IEC/EN/BS 60669-1; IEC 60884-1; except Clause 14, 23, 28.2, 30 Clause 9, 17, 18, 19, 20, only for the National Deviations of Thailand, UK and China; BS 5733; BS 1363-4; BS 1363-2; IEC 60670-1; IEEE C62.41; 47CFR FCC part 15; IEEE C62.41; 47CFR FCC part 18; IEC/EN 62493 IEC/EN 61000-3-2;IEC/EN 62493 IEC/EN 61000-3-3; IEC/EN 62493 IEC/EN 61000-4-2; IEC/EN 62493 IEC/EN 61000-4-4; IEC/EN 62493 IEC/EN 61000-4-5; IEC/EN 62493 IEC/EN 61000-4-11; IEC/EN 61547 exept clause 5.3 5.4 5.6; CISPR 14-1 except cl 4.1.2, 4.1.3, 4.2, annex B; CISPR 14-2 except cl 5.3, 5.4, 5.5; CISPR 15 except cl 4.4.1 and 4.4.2; CISPR 22 except clause 5.2, 6.1, 6.2; CISPR 24 except clause 4.2.3, 4.2.4; IEC 62554 except clause 5.4.4, 5.4.5; IEC 62321-4
IEC/EN 61347-1:2015 All clauses, except clause 13, Annex B, annex E, annex N; IEC/EN 61347-2-1:2015; IEC/EN 61347-2-2:2011; IEC/EN 61347-2-3:2011; IEC/EN 61347-2-7:2011;
IEC/EN 61347-211:2001; IEC/EN 61347-2-12: 2010; IEC/EN 61347-2-13: 2014; IEC/EN 62031:2014; IEC/EN 60929:2013; IEC/EN 60927:2013 * only for ENEC certification, not for IECEE works; IEC/EN 62384:2011; IEC/EN 60598-1:2014 except clause 9; IEC/EN 62717:2015; EPRS-001:2015; IEC 60950-1:2013 except clauses 6 and 7; IEC 60065:2014
All clauses, except clause 6,12, 18, and 19, Annex b – CTF2; IEC 61000-3-2:2014 For Lighting equipment; IEC/EN 61547:2009 All clause except Radiate immunity test (clause 4.3); CSIPR 15:2013; IEC 62493:2015. |
2011-10-17 |
2016-10-27 |
DEKRA-267 |
E-CTF 3 |
VESTEL Product Safety Laboratory |
Vestel Elektronik Sanayi ve Tic. A.S., High End Fabrikasi, Organize Sanayi Bolgesi, Manisa, 45030 |
Turkey |
EN 60065:2014 all except cl. 18 and Annex B; EN 60950-1:2006 All except cl. 2.3 and cl. 6; EN 60950-1:2006/AMD1:2009, AMD2:2013 All except cl. 2.3 and cl. 6; EN 62368-1:2014 Audio/video lab accepted as CTF2; EN 60335-1:2001 All clauses except annex R; EN 60335-1:2001 /AMD1:2004 All clauses except annex R; EN 60335-1:2001 /AMD2:2006 All clauses except annex R; EN 60335-1:2010 All clauses except annex R; EN 60335-1:2010 /AMD1:2013 All clauses except annex R; EN 60335-1:2010 /AMD2:2016 All clauses except annex R; EN 60335-2-24:2010 All clauses except annex R; EN 60335-2-24:2010 /AMD1:2012 All clauses except annex R; EN 60335-2-24:2010 /AMD2:2017 All clauses except annex R; EN 60335-2-40:2002 All clauses except annex R; EN 60335-2-40:2002 /AMD1:2005 All clauses except annex R; EN 60335-2-40:2002 /AMD2:2005 All clauses except annex R; EN 60335-2-40:2013 All clauses except annex R; EN 60335-2-40:2013 /AMD1:2016 All clauses except annex R; EN 60335-2-40:2018 All clauses except annex R; EN 62233:2005; EN 61347-1:2007; EN 61347-1:2007/ A1:2010/A2:2012; EN 61347-2-13:2014+A1:2016; EN 61347-2-11:2011; EN 62384:2006/AMD1:2009; EN 60598-1:2014; EN 60598-2-1:1979/ A1:1987; EN 60598-2-2:2011; EN 60598-2-3:2002/A1:2011; EN 60598-2-5:2015; EN 60529:1989/A1:1999/A2:2013;
EN 62031:2008/A1:2012/A2:2014; EN 62471:2006 exc. cl. 4.3.7 and cl. 4.3.8; EN 62717:2014+A1:2015; EN 62722-1:2014; EN 62722-2-1:2014 |
2013-01-24 |
0000-00-00 |
DEKRA-277 |
E-CTF 1 |
Datalogic ADC Srl |
Via San Vitalino, 13 - 40012 Calderara di Reno (BO) |
Italy |
EN 60950-1 |
2012-09-25 |
0000-00-00 |
DEKRA-279TMP |
E-CTF 1 |
Dongguan Yanlun Electric Co., Ltd |
No.32, 36, Sanjiang Industrial Zone, Hengli Town, 523460, Dongguan, Guangdong |
China |
EN IEC 61058-1: 2018 Accepted clauses:16,17; EN 61058-1-1: 2016 Accepted clauses:16,17; EN 61058-1-2: 2016 Accepted clauses:16,17 |
2019-10-28 |
0000-00-00 |
DEKRA-280-07-AA |
E-CTF 1 |
Ningbo CPX Electronics Technology Co., Ltd. |
58 ALY 101 Zhen-Ning W RD, Jiaochuang ST, Zhenhai Area, 315200 Ningbo, Zhejiang |
China |
EN IEC 61058-1: 2018 Accepted clauses: 14, 16, 17; EN 61058-1-1: 2016
Accepted clauses: 14, 16, 17; EN 61058-1-2: 2016 Accepted clauses: 14, 16, 17; EN 61058-2-5: 2011 Accepted clauses: 14, 16, 17 |
2012-04-16 |
0000-00-00 |
DEKRA-284-06-AA |
E-CTF 1 |
ASIS PRO LTD |
27 Hashaked St Haman Park Industrial Zone |
Israel |
EN 60950-1 |
0000-00-00 |
0000-00-00 |
DEKRA-289/TMP |
E-CTF 3 |
WAGO Kontakttechnik GmbH (nach Schweizer Recht) & Co. KG |
Hansastrasse 27, 32423 Minden |
Germany |
EN 60947-1; 60947-7-1; 60947-7-2; 60947-7-3; 60998-1; 60998-2-1; 60998-2-2; 60998-2-3; 60999; 60999-2; 61535; 61984 |
0000-00-00 |
0000-00-00 |
DEKRA-240 |
E-CTF 1 |
FACEM S.p.A. |
Via Trucchetti, 36 - 10084 Forno Canavese (TO) |
Italy |
EN 60335-1; EN 60335-2-14 |
2012-06-14 |
0000-00-00 |
DEKRA-292/TMP |
E-CTF 3 |
EAE AYDINLATMA A.S |
Eski Turgut Ozal Cad. No:20, Ikitelli Organize Sanayi Bolgesi, 34490 Basaksehir, Istanbul |
Turkey |
EN-60598-2-1; EN 60598-2-2; EN 60598-2-3; EN 60598-2-5 |
2012-08-23 |
0000-00-00 |
DEKRA-293 |
E-CTF 2 |
AEB Industriale Srl |
Via Giacomo Brodolini, 8 – Loc. Crespellano -40053 Valsamoggia (BO) |
Italy |
EN 60065:2001 (Seventh Edition) + A1:2005 + A2:2010
Clauses: 5, 7, 8, 9, 10.2, 10.3, 11, 12 (except for 12.1.2 and 12.5, 12.6), 13, 15.2, 17.1, 17.2, 17.3, 19; EN 60065:2014 (8th Edition) Clauses: 5, 7, 8, 9, 10.2, 10.3, 10.4, 11, 12 (except for 12.1.2 and 12.5, 12.6, 12.7), 13, 15.2, 17.1, 17.2, 17.3, 19 |
2015-10-15 |
0000-00-00 |
DEKRA-296 |
E-CTF 2 |
Test Center of Zhejiang Shenghui Lighting Co., Ltd. |
West Jiachuang Road, Canada Jiaxing Science Based Industrial Zone,
Xiuzhou Industrial Zone, Jiaxing City, Zhejiang Province, China |
China |
EN 60598-1:2015 All clause except clause 4 and 9.2.3 (IPX1)
EN 60598-1:2015/A1:2018 All clause except clause 4 and 9.2.3 (IPX1)
EN 60598-1:2021 All clause except clause 4 and 9.2.3 (IPX1, IPX9, IPX10)
EN 60598-1:2021/A11:2022 All clause except clause 4 and 9.2.3 (IPX1, IPX9, IPX10)
EN 60598-2-1:2021 EN 60598-1:2021 + A11:2022
EN 60598-2-2:2012 EN 60598-1:2015 + A1;2018
EN 61347-1:2015/A1:2021 All clause except clause 13 and 14.
EN 61347-2-13:2014/A1:2017 All clause except clause 14;
EN 62560:2012 All clause except clause 13;
EN 62560:2012/A1:2015 All clause except clause 13;
EN 62560:2012/A11:2019 All clause except clause 13;
EN 62838:2016 All clause except clause 13 |
2021-10-21 |
0000-00-00 |
DEKRA-303 |
E-CTF 1 |
L&S Lighting Equipment (Shanghai) Co., Ltd – Testing Centre |
No 1, Lane 255, Longpan Rd, Malu Town, Jiading District, Shanghai, China |
China |
EN 60598-1:2015 + A1:2018: All clauses except clause 4.4; 4.5; 4.10; 4.11; 4.12.4; 4.12.5; 4.13.4; 4.13.6; 4.14.2; 4.14.6; 4.15; 4.16; 4.17; 4.18; 4.20; 4.21; 4.22; 4.24; 4.26; 9.2.1 to 9.2.9; 12.6; 12.7; 13.3; 13.4; 14;15
EN 60598-2-1:1989: All clauses except clause 1.9.
EN 60598-2-2:2012: All clauses |
2019-03-28 |
2022-12-12 |
DEKRA-303 |
E-CTF 2 |
Steinel GmbH |
Dieselstrasse 80-84, 33442 Herzebrock-Clarholz |
Germany |
EN 60598-1; EN 60598-2-1; EN 60598-2-2; EN 60598-2-4; EN 60598-2-5; EN 60598-2-6; EN 60598-2-7; EN 60598-2-8; EN 61347-1; EN 61347-2-11; EN 61347-2-13; EN 62031 |
2012-08-31 |
0000-00-00 |
DEKRA-305/WMT |
E-CTF 3 |
Busch-Jaeger Elektro GmbH |
Freisenbergstrasse 2, 58513 Lüdenscheid |
Germany |
EN 60884-1; EN 61058-1; EN 60669-1; EN 60669-2-1 |
2001-03-15 |
2013-04-17 |
DEKRA-317 |
E-CTF 3 |
DEHN SE + Co KG |
Hans-Dehn-Strasse 1, , 92318 Neumarkt, Germany |
Germany |
EN 61643-11, EN 50539-11 |
2016-07-11 |
0000-00-00 |
DEKRA-323 |
E-CTF 1 |
Trantek Electronics Co., Ltd. |
No. 288, Jinshi Road 7, Xiaojinkou Town, Huicheng District, Huizhou City 516023, Guangdong Province |
China |
EN IEC 61058-1: 2018 Accepted clauses: 16, 17; EN 61058-1-1: 2016 Accepted clauses: 16, 17; EN 61058-1-2: 2016 Accepted clauses: 16, 17 |
2019-09-30 |
0000-00-00 |
DEKRA-325-07-AA |
E-CTF 1 |
Starhome GmbH |
Seefeldstrasse 25 – 8008 Zurich |
Switzerland |
EN 60950-1 |
2014-01-16 |
0000-00-00 |
DEKRA-332/TMP |
E-CTF 1 |
Viabizzuno srl |
Via Romagnoli, 10 – 40010 Bentivoglio (BO) |
Italy |
EN 60598-1 : Section 3 (Marking) - Section 4 (Construction) except Cl. 4.13.4, Cl. 4.13.6, Cl. 4.14.6, Cl. 4.15.1, Cl. 4.17, Cl. 4.18, Cl. 4.20, Cl. 4.21.2, Cl. 4.21.3, Cl. 4.21.4, Cl. 4.24 - Section 5 (External and internal wiring) - Section 7 (Provision for earthing) - Section 8 (Protection against electric shock) - Section 10 (Insulation resistance and electric strength, touch current and protective conductor current) - Section 11 (Creepage distances and clearances) - Section 12 (Endurance test and thermal test).
EN 60598-2-1 |
2014-01-06 |
2017-06-22 |
DEKRA-335/TMP |
E-CTF 1 |
Scotsman Ice Srl |
Via Puccini 22, 20010 Pogliano Milanese (MI) |
Italy |
EN 60335-1; EN 60335-2-24 |
2014-02-20 |
0000-00-00 |
DEKRA-340/TMP |
E-CTF 2 |
Diebold Nixdorf Systems GmbH |
Heinz-Nixdorf-Ring 1, D-33106 Paderborn |
Germany |
EN 60950-1:2005+A11:2009+A1:2010+A12:2011+A2:2013 All clauses, except: Cl. 4.3.13, Cl. 6.2.2, Cl. 7.4.2, Annex A, Annex H, Annex N, Annex S, Annex Y, Annex AA; EN 60950-22:2016 + A11:2008 All clauses except: annex A, Annex C, Annex D; EN 62368-1:2020 All clauses except: Cl. 5.4.1.10.2, Cl. 5.4.1.10.3, Cl. 5.4.4.6.5, Cl. 5.4.5, Cl. 5.4.7, Cl. 5.4.9, Cl. 5.4.10, Cl. 5.4.12, Cl. 9.6, Cl. 10, Annex C, Annex D, Annex G.13.3, Annex G.13.6, Annex G.14, Annex G.15, Annex H, Annex S |
2014-07-02 |
2019-07-12 |
DEKRA-346-08-AA |
E-CTF 1 |
POLTI S.p.A. |
Via Ferloni, 83 - 22070 Bulgarograsso (Como) |
Italy |
EN 60335-1; EN 60335-2-54; EN 60335-2-3; EN 60335-2-2; EN 60335-2-15 |
0000-00-00 |
2014-07-07 |
DEKRA-347/TMP |
E-CTF 3 |
PHOENIX CONTACT GmbH & Co. KG |
TRABTECH Testlaboratory, Flachsmarktstraße 8
D-32825 Blomberg, Germany |
Germany |
EN 61643-11, EN 50539-11 |
2016-07-11 |
0000-00-00 |
DEKRA-353 |
E-CTF 1 |
Xiamen Yankon Energetic Lighting Co., Ltd. |
No. 88 Houxiang Road
Haicang District
Xiamen - Fujian 361026
P.R.China |
China |
EN 61347-1:2015 All clauses except: cl.8, cl.18.2 and Annex B, C, N; EN 61347-2-13:2014; EN 61347-2-13:2014/A1:2017; EN 60598-1:2015 All clauses except: cl.4.4.5, cl.4.5, cl.4.11.6, cl.4.20, cl.4.24, cl.12.5.1, cl.12.7, cl.14 and cl.15; EN 60598-1:2015/A1:2018 All clauses except: cl.4.4.5, cl.4.5, cl.4.11.6, cl.4.20, cl.4.24, cl.12.5.1, cl.12.7, cl.14 and cl.15; EN 60598-2-1:1989; EN 60598-2-2:2012; EN 62560: 2012 All clauses except:cl.17; EN 62560: 2012/A1:2015 All clauses except:cl.17 |
0000-00-00 |
0000-00-00 |
DEKRA-364 |
E-CTF 2 |
AEC ILLUMINAZIONE s.r.l. |
Via A. Righi, 4 - Z.I. Castelnuovo, 52010 SUBBIANO (AR) Italy |
Italy |
EN 60598-1:2014 All clauses except: Clause 13.3.1 Needle-flame test, Clause 13.3.2 Glow-wire test, Clause 13.4 Proof tracking test, EN 60598-2-1:1979 + A1:1987, EN 60598-2-2:2011, EN 60598-2-3:2002 + A1:2011, EN 60598-2-5:1998, EN 62031:2008 + A1:2012 + A2:2014 All clauses except: Clause 14 fault conditions, EN 60598-2-24:2013 |
2016-07-07 |
0000-00-00 |
DEKRA-372 |
E-CTF 1 |
EWO |
Via dell’Adige 15,
39040 Cortaccia (BZ) - ITALY |
Italy |
EN 62031:2008 +A1:2012 +A2:2014 All clauses except:
Provisions for protective earthing; Protection against accidental contact with live parts; Moisture resistance and insulation; Resistance to heat, fire and tracking; Resistance to corrosion.
EN 60598-1:2014 All clauses except: Construction Clause 4.13 Mechanical strength; Clause 4.15 Flammable materials; Clause 4.18 Resistance to corrosion; Clause 4.20 Rough service luminaires; Clause 4.24 Photobiological hazards.
Provision for earthing; Protection against electric shock; Clause 8.2 Protection against electric shock; Resistance to dust, solid objects and moisture; Endurance test and thermal test; Resistance to heat, fire and tracking; Screw less terminals and electrical connections.
EN 60598-2-1:1979 All clauses
EN 60598-2-3:2002+A1:2011 All clauses
EN 60598-2-5:1998 All clauses. |
2015-08-06 |
0000-00-00 |
DEKRA-376 |
E-CTF 1 |
Datalogic Automation |
Via Lavino 265- 40050 Monte San Pietro (BO) Italy |
Italy |
EN 60825-1 2nd ed, EN 60825-1 3rd ed. |
2011-07-02 |
0000-00-00 |
DEKRA-385 |
E-CTF 3 |
ETAP NV |
Antwerpsesteenweg 130, 2390 Malle |
Belgium |
EN 60598-1, EN 60598-2-1, EN 60598-2-2, EN 60598-2-19, EN 60598-2-22, EN 60598-2-24, EN 62031:2008/AMD1:2013/AMD2:2015 (Only led modules with passive components. Blue-light hazard is pending), EN 62262/IEC/TR 62969 (IK application for luminaires) |
2016-01-18 |
2019-06-13 |
DEKRA-382 |
E-CTF 2 |
Reggiani Illuminazione S.p.A |
Viale Monza, 16 20845, Sovico (MB) |
Italy |
EN 60598-1:2014 All clauses except: 4.18.2 Stress Corrosion, 9.2.1 Dust Proof (first index IP), 13.3.1 Resistance to Flame Tests, 13.4.1 Resistance to Tracking Tests; EN 60598-2-1:1979; EN 60598-2-2:2011; EN 60598-2-6:1994+A1:1996; EN 60598-2-13:21632006) +A1 (2011); EN 62031:2008+A1:2012+A2:2014 All clauses, except: 18 Resistance to Heat, Fire and Tracking (Needle flame burner, Tracking test apparatus) 19 Resistance to Corrosion. |
2016-05-09 |
0000-00-00 |
DEKRA-386 |
E-CTF 1 |
Cooper Csa Srl |
Via San Bovio 3 –Edificio Y
20090 Segrate (MI) |
Italy |
EN 61347-1 (ALL, except :
Clause 9.1, Provision for protective earthing
Clause 11 Moisture resistance and insulation
Clause 14.5 Fault condition.
Clause 18.1, 18.2, 18.3, 18.4 resistance to heat, fire and tracking), 61347-2-7 (ALL except annex K clause 4.4.6) |
2016-05-19 |
0000-00-00 |
DEKRA-388 |
E-CTF 2 |
E.G.O. Gerätebau GmbH |
Rote-Tor-Straße 14, 75038 Oberderdingen, Germany |
Germany |
IEC 60730-1 All clauses for electronic controls, except for 23 and 26; IEC 60730-2-9 See 60730-1
IEC 60335-1 Accepted clauses: 19.11 (except for 19.11.4), 22.46, 29 and 30, Annex R
IEC 60335-2-6 See 60335-1 |
2016-10-13 |
0000-00-00 |
DEKRA-402-01-IA |
E-CTF 1 |
Jiangmen Krealux Electrical Appliances Co., Ltd |
No.2, Block 1, 2, Jinxi Road, Jianghai District, 529080, Jiangmen, Guangdong |
China |
EN/IEC 61058-1:2018 All clauses except: 23, 24, 25, for clause 17, test resistive load and tungsten filament lamp load; EN 61058-1-1:2016 All clauses except: 23, 24, 25, for clause 17, test resistive load and tungsten filament lamp load; EN 61058-2-1: 2021 All clauses except: 23, 24, 25, for clause 17, test resistive load and tungsten filament lamp load; EN 61984: 2009 All clauses except: 6.21, 7.3.14
EN 60998-1: 2004, EN 60998-2-1: 2004 All clauses; EN 60998-1: 2004, EN 60998-2-2: 2004 All clauses; EN IEC 60670-1:2021 All clauses except: 12.2.3.4, 12.2.3.5, 12.13, 15.2 |
2017-07-13 |
0000-00-00 |
DEKRA-419-05-AA |
E-CTF 3 |
Signify Poland Sp. z o.o. |
ul. Kossaka 150, 64-920 Pi?a |
Poland |
EN 60432-1 lamps; EN 60432-2 lamps; EN 60432-3 lamps; EN 60357 lamps; EN 60064 lamps; EN 60081 lamps; EN 60901 lamps; EN 61195 lamps; EN 61199 lamps |
2019-03-11 |
0000-00-00 |
DEKRA-430 |
E-CTF 1 |
Zhejiang KLITE Lighting Holdings Co.,Ltd -Testing Center |
2F, Block B, Jianxing Building, No.3151, Shahe West Road, Xili, Nanshan District, Shenzhen, 518055 |
China |
EN 62384:2006+A1:2009 All clauses; EN 62031:2008+A1:2013+A2:2015; All clauses, except Cl. 18,5 of EN 61347-1; EN 62722-1:2016 All clauses; EN 62722-2-1:2014 All clauses; EN 62722-2-1:2016 All clauses |
2019-02-07 |
0000-00-00 |
DEKRA-439 |
E-CTF 2 |
BSH Electrodomesticos Espana, S.A. |
Avda. de la Industria, 49, 50016 ZARAGOZA, SPAIN |
Spain |
IEC/EN 60335-1 All clauses, except for 19.11.4 (EMC); IEC/EN 60335-2-6 All clauses, except for 19.11.4 (EMC) |
2018-10-23 |
2018-10-23 |
DEKRA-460 |
E-CTF 2 |
Signify Luminaires (Shanghai) Co., Ltd. Laboratory |
Building 9,Lane 888, Tianlin Road, Shanghai, China |
China |
EN 6059-1:2021/A11:2022 All clauses except cl 4.13.3, cl 4.20, cl4.24, cl 4.26, cl 4.34, cl 9.2.3, cl 9.2.9, cl 9.2.10, cl 9.2.11; EN IEC 60598-2-1: 2021 Including all valid editions and all clauses except cl: cl4.13.6, cl. 4.20, cl 4.24, cl 4.26, cl 4.34, cl 9.2.3, cl 9.2.9, cl 9.2.10, cl 9.2.11 in EN 60598-1; EN 60598-2-4: 2018 Including all valid editions and all clauses except cl 4.13.6, cl 4.20, cl 4.24, cl 4.26, cl 9.2.3, cl 9.2.9 in EN 60598-1:2015+A1:2018; EN 60598-2-13:2006 + A11:2021+A1:2012+A2:2016 Including all valid editions and all clauses except cl 4.13.6, cl 4.20, cl 4.24, cl 4.26, cl 9.2.3, cl 9.2.9 in EN 60598-1 and cl 13.6.1, cl13.6.2.2 in EN 60598-2-13; EN 60598-2-1: 1989 Including all valid editions and all clauses except cl 4.13.6, cl 4.20, cl 4.24, cl 4.26, cl 9.2.3, cl 9.2.9 in IEC 60598-1; EN 60598-1: 2015 Including all valid editions and all clauses except cl 4.13.6, cl 4.20, cl 4.24, cl 4.26, cl 9.2.3, cl 9.2.9 in IEC 60598-1; EN 60598-2-2: 2012 Including all valid editions and all clauses except cl: cl4.13.6, cl. 4.20, cl 4.24, cl 4.26, cl 4.34, cl 9.2.3, cl 9.2.9, cl 9.2.10, cl 9.2.11 in EN 60598-1; EN 60598-2-3: 2003+A1:2011 Including all valid editions and all clauses except cl: cl4.13.6, cl. 4.20, cl 4.24, cl 4.26, cl 4.34, cl 9.2.3, cl 9.2.9, cl 9.2.10, cl 9.2.11 in EN 60598-1; EN 60598-2-4: 1997 Including all valid editions and all clauses except cl 4.13.6, cl 4.20, cl 4.24, cl 4.26, cl 9.2.3, cl 9.2.9 in IEC 60598-1; EN 60598-2-5: 2015 Including all valid editions and all clauses except cl cl4.13.6, cl. 4.20, cl 4.24, cl 4.26, cl 4.34, cl 9.2.3, cl 9.2.9, cl 9.2.10, cl 9.2.11 in EN 60598-1; EN 60598-2-13: 2006+A1:2012+A2:2016 Including all valid editions and all clauses except cl 4.13.6, cl 4.20, cl 4.24, cl 4.26, cl 9.2.3, cl 9.2.9 in EN 60598-1 and cl 13.6.1, cl13.6.2.2 in EN 60598-2-13 |
2021-01-11 |
0000-00-00 |
DEKRA-463 |
E-CTF 3 |
Philips (China) Investment Co., Ltd. |
Standard Test laboratory, No. 9, Lane 888, Tian Lin Road, 200233 Shanghai |
China |
EN 61347-1:2015 All clauses except clause 13 Annex B, E, N; EN 61347-2-1:2001 + A1:2006 + A2:2014; EN 61347-2-2; EN 61347-2-3:2011+A1:2017; EN 61347-2-7:2012; EN 61347-2-11:2001 |
2011-01-24 |
2013-06-17 |
DEKRA-464 |
E-CTF 1 |
OSRAM Asia Pacific Management Company |
2F, Block B, Jianxing Building, No.3151, Shahe West Road, Xili, Nanshan District, Shenzhen, 518055 |
China |
EN 61347-2-13:2014 + A1:2017 All clauses; EN 61347-1:2015 All clauses except 18.2, 18.5 and Annex N; EN 62031: 2008 + A1: 2013 + A2:2015 All clauses except 18.2 and 18.5 |
2019-02-07 |
0000-00-00 |
DEKRA-467-01-SE |
E-CTF 3 |
Signify Belgium N.V. |
Steenweg op Gierle 417, 2300 Turnhout |
Belgium |
EN62035:2014/AMD1:2016 All; EN61167:2018/AMD1:2018 All; EN 60662:2011/AMD11:2019 All; EN 60188:2001/AMD11:2019 All; EN 62717:2017 All except cl. 8.2; EN 62722-2-1:2016 Only cl. 10 |
2017-10-23 |
2019-02-25 |
DEKRA-469 |
E-CTF 3 |
Signify (China) Investment Co., Ltd,
(Lighting Test Center -LTC) |
No.9, Lane 888, Tian Lin Road
Shanghai, P.R. China 200233 |
China |
EN 61347-1:2015 /All clauses except clause 13, Annex B annex E
EN 61347-2-1:2001
EN 61347-2-1:2001/AMD1:2006
EN 61347-2-1:2001/AMD2:2014
EN 61347-2-3:2011
EN 61347-2-3:2011/AMD1:2017
EN 61347-2-2 : 2012
EN 61347-2-7:2012
EN 61347-2-11:2001
EN 61347-2-11:2001/AMD1:2019
EN 61347-2-12:2005
EN 61347-2-12:2005/AMD1:2010
EN 61347-2-13:2014
EN 61347-2-13:2014/AMD1:2017
EN 62031:2008
EN 62031:2008/ AMD1:2013
EN 62031:2008/ AMD2:2015
EN 60598-1:2015: All clause except section 3, 4 and 12
EN 60598-1:2015/AMD1:2018 :All clause except section 3, 4 and 12
EN 60950-1:2006 :All clauses, except clauses 6 and 7
EN 60950-1:2006/AMD11:2009: All clauses, except clauses 6 and 7
EN 60950-1:2006/AMD1:2010: All clauses, except clauses 6 and 7
EN 60950-1:2006/AMD12:2011: All clauses, except clauses 6 and 7
EN 60950-1:2006/AMD2:2013: All clauses, except clauses 6 and 7
EN 60065:2014: All clauses except Clause 4.1, 4.6.1, 5.1- 5.7, 6.1- 6.4, annex B, F, G, O, T, L
EN 60065:2014/AMD11:2017: All clauses except Clause 4.1, 4.6.1, 5.1- 5.7, 6.1- 6.4, annex B, F, G, O, T, L
EN 62368-1:2014: All clauses except Clause 4.1, 4.6.1, 5.1- 5.7, 6.1- 6.4, annex B, F, G, O, T, L
EN 62368-1:2014/AMD11:2017: All clauses except Clause 4.1, 4.6.1, 5.1- 5.7, 6.1- 6.4, annex B, F, G, O, T, L
EN 60927:2007
EN 60927:2007/AMD1:2013
EN 60929 2011
EN 60929 2011/AMD1:2016
EN 62384:2006
EN 62384:2006/AMD1:2009
EN 62717:2017: All clauses except clause 8, 9, 10.2
EN 55015:2013: All clause except clause 4.4.2
EN 55015:2013/AMD1:2015: All clause except clause 4.4.2
EN 61000-3-2:2014: Only for lighting equipment’s
EN 61547:2009: All clause except clause 5.3, 5.4
EN 62493:2015: All clauses except clause 7
EN IEC 55015:2019: All clause except clause 4.5.3
EN IEC 55015:2019/AMD11:2020: All clause except clause 4.5.3
EN IEC 61000-3-2:2019
EN IEC 62368-1:2020: All clauses except Clause 4.6.1, 5.8, 7, 8.3-8.6, 9, 10, annex C, E, H, J, K, M, N, R, U, Y
EN IEC 62368-1:2020/AMD11: 2020:All clauses except Clause 4.6.1, 5.8, 7, 8.3-8.6, 9, 10, annex C, E, H, J, K, M, N, R, U, Y
EN IEC 62031:2020 |
0000-00-00 |
0000-00-00 |
DEKRA-464 |
E-CTF 3 |
Signify Belgium0 N.V. |
Steenweg op Gierle 417, 2300 Turnhout |
Belgium |
EN 62035:2014/AMD1:2016 All; EN 61167:2018/AMD1:2018 All; EN 60662:2011/AMD11:2019 All; EN 60188:2001/AMD11:2019 All; EN 62717:2017 All except cl. 8.2; EN 62722-2-1:2016 Only cl. 10 |
2015-03-26 |
2019-03-07 |
DEKRA-470 |
E-CTF 2 |
Wilo SE Werk Hof |
Heimgartenstraße 1-3, 95030, Hof |
Germany |
EN 60335-1 All clauses, except: 30, 32, IPx8; no test finger and impact hammer available; EN 60335-2-41 All clauses, except: 30, 32, IPx8; no test finger and impact hammer available |
2019-07-23 |
0000-00-00 |
DEKRA-493 |
E-CTF 2 |
DEKRA Testing and Certification GmbH |
Enderstrasse 92b, 01277 Dresden |
Germany |
EN 60598-1:2015; EN 60598-1:2015/A1:2018 All clauses except the following ones: 4.20 (vibration test for rough service luminaires), 9.2.9 (IPX8), 13.3.1 (needle flame test), 13.3.2 (glow wire); EN 60598-2-1:1989 All clauses; EN 60598-2-2:2012 All clauses; EN 60598-2-3:2003 + A1:2011 All clauses; EN 60598-2-4:2018 All clauses; EN 60598-2-5:2015 All clauses; EN 60598-2-13:2006 + Cor.:2006 + A1:2012 + A2:2016 All clauses; EN 60598-2-18:1994 + Cor.:1996 + A1:2012 All clauses; EN 60598-2-22:2014 All clauses; EN 60598-2-24:2013 All clauses; EN IEC 62031:2020 All clauses; EN 13032-1:2004 + A1:2012 All clauses; EN 13032-2:2017 All clauses; EN 13032-3:2007 All clauses; EN 13032-4:2015 All clauses; EN 62471:2008 All clauses; DIN IEC/TR 62778:2014; DIN SPEC 62778:2014; PD IEC/TR 62778:2014-31 All clauses |
2020-04-30 |
0000-00-00 |
DEKRA-518 |
E-CTF 1 |
Ningbo Master Soken Electrical Co., Ltd. |
No. 19 Zongyan Road, Xikou Industry Zone, Xikou, Ningbo |
China |
EN IEC 61058-1: 2018 Clauses 16, 17, 20; EN 61058-1-1: 2016 Clauses 16, 17, 20 |
2020-10-19 |
0000-00-00 |
DEKRA-354-04-AA |
E-CTF 1 |
Fortech Industrial (Shenzhen) Limited |
1st & 2nd Floor, Block 1, Lot A1-2, 3rd Yanshan Avenue Industrial Park, Yanchuan Community, Yanluo Street, Bao'an District, 518127, Shenzhen City, Guangdong Province, |
China |
EN IEC 61058-1: 2018 Clauses 15, 16, 17, 18,2, 18,4, 21; EN 61058-1-1: 2016 Clauses 15, 16, 17, 18,2, 18,4, 21 |
2020-10-19 |
0000-00-00 |
DEKRA-492-02-AA |
E-CTF 3 |
Bosch Lawn and Garden Limited |
Suffolk Works, Stowmarket, Suffolk IP14 1EY |
United Kingdom |
EN ISO 3744:1995 All clauses except clause 7.3, annex C for EN ISO 3744:1995; EN ISO 3744:2010 All clauses except clause 7.2.4, 7.2.5, 7.2.6, Annex C, Annex D for EN ISO 3744:2010; ISO 11094:1991 All clauses; EN 60335—2-77:2010 Accepted clauses: Annex GG; EN 50636-2-107:2015 + A1:2018 Accepted clauses: Annex FF; EN 50636-2-91:2014: Accepted clauses: Annex CC |
2020-02-27 |
0000-00-00 |
DEKRA-507 |
E-CTF 2 |
OSRAM Asia Pacific Management Company |
2F, Block B, Jianxing Building, No.3151, Shahe West Road, Xili, Nanshan District, Shenzhen, 518055, P.R. |
China |
EN 61347-2-13: 2014 + A1: 2017 All clauses; EN 61347-1: 2015 All clauses except 18.2, 18.5 and Annex N; EN 62031: 2008 + A1: 20123 + A2: 2015 All clauses except 18.2 and 18.5; EN IEC 62031: 2020 All clauses except 18.2 and 18.5; EN 60598-1: 2015 + A1: 2018 All clauses except 4.26, 8.2.5, 9.2.1,2,3, 10.3.2 and 13.4.1 |
2020-05-14 |
0000-00-00 |
DEKRA-516-01-IA |
E-CTF 1 |
Sing Fai Electrc (Dong Guan) Co., Ltd. |
213-2, Bubugao Road, Jiang Bei Village, Wuzar Chang An
Dong Guan, Guangdong |
China |
EN 61058-1:2018 Accepted clauses: 16, 17; EN 61058-1-1:2016 Accepted clauses: 16, 17 |
2021-05-17 |
0000-00-00 |
DEKRA-528 |
E-CTF 1 |
Dongguan Huaconn Electronics Co, . Ltd. |
No 11. Wangjiao Road, Hengtang, Tangxia Town, 253713, Dongguan City, Guangdong Province |
China |
EN 61058-1-1:2016 Accepted clauses 16, 17; EN 61058-1:2018 Accepted clauses 16, 17 |
0000-00-00 |
0000-00-00 |
DEKRA-547 |
E-CTF 3 |
Lightning Research Institute of Catalonia, S.L. |
C/Navas de Tolosa, 44 08223 TERRASSA BARCELONA SPAIN |
Spain |
EN 61643-11:2012+A11:2018 All clauses except: 8.3.5.3 Short-circuit current behaviour tests and 8.6.1.3 Load-side short-circuit current behaviour test; |
2022-02-17 |
0000-00-00 |
DEKRA-549 |
E-CTF 1 |
Hengdian Group Tospo Lighting Co., Ltd. |
Hengdian Electronics Industrial Zone, Dongyang Zhejiang, |
China |
EN 60598-1:2015+A1:2018 All clauses exceptcl.4.26, cl.9.2.8, cl.9.2.9; EN 60598-1:2021 All clauses except cl.4.13.6, cl. 4.26, cl 4.34, cl.9.2.8, cl. 9.2.9, cl9.2.10, cl. 9.2.11; EN 60598-2-1:1989 All clauses; EN 60598-2-1:2021 All clauses |
2022-04-28 |
0000-00-00 |
- |
E-CTF 3 |
Stanley Black & Decker Deutschland GmbH |
Black& Decker Strasse 40
65510 Idstein |
Germany |
EN 60547-1:2009+A11:2010, clause 6
EN 60547-2-3:2011+A11:2014+A12:2014 +A13:2015+A2:2013: clause 6
EN 60547-2-6:2010: clause 6
EN 60547-2-12:2009: clause 6
EN 60547-2-13:2009+A1:2010: clause 6
EN 60547-2-15:2019+A1:2010: clause 6
EN 60547-2-16:2010: clause 6
EN 60547-2-18:2009: clause 6
EN 60745-2-19:2009 + A1 2010: clause 6
EN 60547-2-20:2009: clause 6
EN 60547-2-20:2009: clause 6
EN 60547-2-21:2009 + A1;2010: clause 6
EN 60547-2-22:2011+ A11:2013: clause 6
EN 60547-2-23:2013: clause 6
EN 61029-1:2009 + A11:2010: clauses 13.2 and 13.3
EN 61029-2-3:2011: clauses 13.2 and 13.3
EN 61029-2-5:2011 + A11;2015: clauses 13.2 and 13.3
EN 61029-2-8:2010: clauses 13.2 and 13.3
EN 61029-2-11:2012 + A11:2013: clauses 13.2 and 13.3
EN 61029-2-12:2011: clauses 13.2 and 13.3 |
2022-11-24 |
0000-00-00 |
DEKRA-546 |